TUFFA 2500HBFP Fire Pro Bunded Heating Oil Tank with Integral Fire Protection
Product Code: TUFFA 2500HBFP
Description
TUFFA's Fire Protected tank range consists of a plastic inner and outer tank with a " fire barrier " around the inner tank to provide fire resistance. This allows the tank to be located within 1.8m of combustible structures, in openings in buildings and eaves and the tank can be positioned within 760mm of a combustible boundary.
Features:
- Integral Fire retardant material
- 2” BSP fill connection c/w cap and chain
- Vent
- Gas strut assisted flip lid
- 1” bottom outlet (10mm top outlet available upon request)
- Overfill prevention valve *this reduces the working capacity to that shown below
- Clock Gauge
- Electronic Watchmansonic contents gauge
- Colour: Green
- Fittings Pack (1” ‐ 1/2” adaptor, ball valve and filter)
Specification:
| Model No: | 2500HBFP |
| Nominal Capacity (litres): | 2438* |
| Length (mm): | 2840 |
| Width (mm): | 1520 |
| Height (mm): | 1630 |
| Weight (kg): | 320 |
| Overfill Preventer: | Yes |
| Outlet: | 1" BSP F |
* after overfill prevention valve.
Fire Pro Benefits:
The key benefits of a TUFFA Fire Protected tank are:
- They are cost-effective
- Can be located alongside buildings and boundaries
- No additional fireproofing works are required
In addition, the fire barrier is constructed from a high-quality fire retardant material, with the following achievements:
- Independently tested to BS476 : Part 22:1987
- Independently tested to BS476 (Warrington Fire Research Centre)
- Meets section J 5.4 of building regulations, Table 5.1 for Fire Protection for Oil Storage Tanks
- CE Marked in accordance with EN13341 and the Construction Products Regulations
Fire Resistance - 30 minutes of fire resistance is acceptable for domestic installations whereas the optional 60 minute resistance is required for commercial installations
Outlet Options - This tank is supplied with a 1" BSP Bottom Outlet as Standard, a 10mm top outlet is available if required.
Offload Options - This product can be delivered with a HIAB offload, alternatively, you can provide your own offloading facilities on-site. Offloading is to the side of the vehicle only.
Installation:
All TUFFA Fire Protected tanks should be installed on a level non-combustible base which extends 300mm beyond the perimeter of the tank (with the exception of any sides which are adjacent fire rated walls - in this case, a minimum of 100mm should be provided). The installation should be completed by a competent person and signed off through building control or a competent persons scheme (such as APHC).
Register your tank warranty here.
Delivery:
FREE delivery of this product includes most UK mainland locations, however postcodes DD, DG, TD, PH, IV, KW, HS, AB, PA, KA, ML, EH, KY, FK and G as well as offshore locations will incur an additional delivery surcharge. Please contact us prior to ordering so we can quote the additional costs. This product is delivered to the kerbside - it is the customer's responsibility to offload this tank from the delivery vehicle.
If you require any further assistance, please contact us with your requirements or call 0117 244 4099 so one of our sales team can help with your enquiry.